Williams Products

Masonry

Masonry

Everlastic® Backer Rod

Standard & Soft Type Backer Rod for Masonry Construction

Sealant Backing for Masonry Expansion Joints, Control Joints & Building Envelope Applications

Standard and Soft Type Backer Rod from Williams Products provide contractors with professional sealant backing solutions for brick, block, stone, precast, concrete, and building-envelope joints.

Backer rod is installed behind elastomeric sealants to help control sealant depth, support the sealant during installation, reduce sealant consumption, and help prevent three-sided adhesion.

Properly selected and installed backer rod plays an important role in creating a sealant joint that can accommodate movement throughout the life of the building.

Williams Products offers two primary backer rod options for masonry construction:

Standard Backer Rod – Closed-Cell Polyethylene
ASTM C1330 Type C | ASTM D5249 Type 3

Soft Type Backer Rod – Bi-Cellular Polyethylene
ASTM C1330 Type B | ASTM D5249 Type 3

Why Backer Rod Is Important in Masonry Sealant Joints

Masonry buildings contain numerous joints that must accommodate movement while helping prevent the passage of air and water through the building envelope.

Simply filling a deep joint completely with sealant is generally not the best approach.

Backer rod is installed behind the sealant to help establish the proper joint configuration.

A properly installed backer rod helps:

  • Control sealant depth
  • Support the sealant during installation
  • Reduce unnecessary sealant consumption
  • Create consistent sealant geometry
  • Provide a bond-breaking surface behind the sealant
  • Help prevent three-sided adhesion
  • Improve sealant installation
  • Accommodate variations in joint depth

Helps Prevent Three-Sided Sealant Adhesion

One of the most important functions of backer rod is helping create the proper sealant joint configuration.

In a typical moving joint, the sealant should adhere to the two opposing sides of the joint.

The sealant should generally not bond to the bottom.

If the sealant adheres to both sides and the bottom of the joint, three-sided adhesion can occur.

Three-sided adhesion can restrict the sealant’s ability to stretch and compress as the joint moves.

Backer rod provides a bond-breaking surface behind the sealant, helping create the desired two-sided sealant adhesion.

Proper Joint Design

Two-Sided Adhesion = Allows the Sealant to Move

Three-Sided Adhesion = Can Restrict Sealant Movement

This makes backer rod much more than simply a material used to fill empty space behind the sealant.

It is an important part of the complete masonry sealant joint.

Standard Backer Rod

Closed-Cell Polyethylene Backer Rod

Standard Backer Rod is a flexible, closed-cell polyethylene foam used in a wide variety of masonry and construction sealant joints.

It provides a resilient backing surface behind the sealant while helping establish the required sealant depth.

Specifications

ASTM C1330 Type C
ASTM D5249 Type 3

Key Features

  • Closed-cell polyethylene construction
  • Low moisture absorption
  • Flexible and resilient
  • Controls sealant depth
  • Provides support behind sealant
  • Helps reduce sealant consumption
  • Provides a bond-breaking surface
  • Helps prevent three-sided adhesion
  • Available in multiple diameters
  • Lightweight and easy to install

Where Standard Backer Rod Is Used in Masonry

Standard Backer Rod is well suited for uniform masonry and building-envelope joints where the backer rod can be installed at the proper compression.

Typical applications include:

  • Brick expansion joints
  • CMU control joints
  • Masonry expansion joints
  • Building perimeter joints
  • Masonry-to-concrete joints
  • Precast-to-masonry joints
  • Window perimeter joints
  • Door perimeter joints
  • Curtain wall transitions
  • Architectural masonry joints
  • Concrete joints adjacent to masonry

Brick Expansion Joints

Brick masonry requires properly designed movement joints to accommodate expansion and other building movement.

Backer rod is commonly installed behind the sealant within these joints.

Standard Backer Rod helps establish a consistent sealant depth while providing a resilient backing surface.

Typical assembly:

Brick → Backer Rod → Elastomeric Sealant → Brick

The backer rod is recessed into the joint to provide the space required for the specified sealant thickness.

CMU Control Joints

Concrete masonry walls commonly incorporate vertical control joints to accommodate drying shrinkage and other movement.

At the exposed face of the control joint, backer rod and sealant can be used to create a flexible finished joint.

A typical CMU control joint may include:

CMU / Sash Block → Rubber Control Joint → Backer Rod → Sealant

Williams Products can supply both the rubber masonry control joint and backer rod, providing contractors and distributors with multiple components required for the complete assembly.

Masonry-to-Concrete Joints

Brick and block frequently meet concrete structural components throughout a building.

These interfaces can require flexible sealant joints because the adjoining materials may move differently.

Standard Backer Rod can be used in appropriate joints between masonry and:

  • Concrete columns
  • Concrete walls
  • Foundations
  • Structural slabs
  • Precast concrete
  • Architectural concrete
  • Building perimeter concrete

Window & Door Perimeter Joints

Windows and doors create important transitions within masonry wall systems.

Sealant joints around these openings help accommodate movement and protect the building envelope.

Backer rod can be installed behind perimeter sealants around:

  • Windows
  • Doors
  • Storefront systems
  • Louvers
  • Architectural openings
  • Precast openings
  • Other building-envelope penetrations

Soft Type Backer Rod

Bi-Cellular Polyethylene Backer Rod

Soft Type Backer Rod provides a softer and more compressible alternative to traditional closed-cell backer rod.

Its bi-cellular polyethylene construction allows the material to conform more easily to variations in joint width and irregular joint surfaces.

Specifications

ASTM C1330 Type B
ASTM D5249 Type 3

Key Features

  • Bi-cellular polyethylene construction
  • Soft and highly compressible
  • Easily conforms to irregular joints
  • Excellent for variable joint widths
  • Controls sealant depth
  • Provides support behind sealant
  • Helps reduce sealant consumption
  • Provides a bond-breaking surface
  • Helps prevent three-sided adhesion
  • Easier installation in difficult joint configurations

Where Soft Type Backer Rod Is Used in Masonry

Masonry joints are not always perfectly uniform.

Brick, block, stone, mortar, concrete, and field construction tolerances can create joints that vary in width and depth.

Soft Type Backer Rod is particularly useful where the joint opening is irregular, inconsistent, or difficult to fill with a firmer closed-cell backer rod.

Typical applications include:

  • Irregular brick joints
  • Variable-width masonry joints
  • Stone masonry
  • Restoration work
  • Renovation projects
  • Irregular CMU joints
  • Window and door perimeter joints
  • Precast-to-masonry transitions
  • Architectural masonry
  • Difficult building-envelope joints

Excellent for Irregular Joint Openings

One of the biggest advantages of Soft Type Backer Rod is its ability to conform to irregular surfaces.

Masonry construction often includes joints where:

  • Width changes along the joint
  • Mortar protrudes into the opening
  • Brick dimensions vary
  • Stone surfaces are uneven
  • Concrete surfaces are irregular
  • Existing joints have deteriorated
  • Field conditions differ from the original drawings

The softer bi-cellular construction allows Soft Type Backer Rod to compress and adapt to these conditions.

Masonry Restoration & Renovation

Soft Type Backer Rod is particularly useful for restoration and renovation projects.

Existing masonry joints are often less uniform than joints in new construction.

After old sealant and deteriorated material are removed, the remaining joint may contain:

  • Uneven surfaces
  • Variable joint widths
  • Irregular mortar
  • Existing construction tolerances
  • Surface deterioration
  • Non-uniform joint depths

Soft Type Backer Rod can conform more readily to these irregular conditions, making it an excellent option for masonry restoration and resealing applications.

Standard vs. Soft Type Backer Rod

Choosing the correct backer rod depends on the joint configuration and installation conditions.

Choose Standard Backer Rod When:

  • Joint dimensions are relatively consistent
  • Closed-cell construction is preferred
  • Low moisture absorption is important
  • A traditional backer rod installation is required
  • The joint provides adequate space for proper compression

Choose Soft Type Backer Rod When:

  • Joint dimensions vary
  • Masonry surfaces are irregular
  • Greater compressibility is required
  • Installation access is difficult
  • The project involves restoration or renovation
  • A softer material will make installation easier

Both products provide the important functions of sealant depth control, sealant support, and bond breaking.

Selecting the Correct Backer Rod Size

Proper sizing is important for successful backer rod installation.

Backer rod should generally be selected so that it is larger than the joint opening and remains under compression after installation.

This helps keep the material securely positioned within the joint while the sealant is installed.

The required diameter depends on:

  • Joint width
  • Joint depth
  • Backer rod type
  • Joint configuration
  • Sealant requirements
  • Manufacturer recommendations

Williams Products offers backer rod in a variety of diameters to accommodate different masonry joint widths.

Reduces Sealant Consumption

Deep masonry joints can require a significant amount of sealant if the joint cavity is filled completely.

Backer rod fills the unused depth of the joint and establishes the proper location for the sealant.

This can substantially reduce the amount of sealant required while helping create a more consistent finished joint.

For large commercial masonry projects containing thousands of feet of sealant joints, proper backer rod installation can provide meaningful material savings.

Typical Masonry Applications

Standard and Soft Type Backer Rod can be used in a wide range of masonry applications, including:

  • Brick expansion joints
  • CMU control joints
  • Masonry expansion joints
  • Building perimeter joints
  • Masonry-to-concrete joints
  • Precast-to-masonry joints
  • Window perimeter joints
  • Door perimeter joints
  • Storefront joints
  • Curtain wall transitions
  • Architectural masonry
  • Stone masonry
  • Restoration projects
  • Renovation projects
  • Exterior wall joints
  • Interior masonry joints

Industries & Markets Served

Masonry Construction | Brick Construction | Concrete Masonry | Building Envelope | Commercial Construction | Institutional Construction | Industrial Construction | Architectural Masonry | Masonry Restoration | Multi-Family Construction

Why Choose Williams Products for Backer Rod?

Williams Products supplies both Standard and Soft Type Backer Rod, allowing contractors and distributors to select the appropriate material for the specific joint condition.

Whether you’re working with a consistent new-construction masonry joint or an irregular restoration joint, Williams Products can help supply the backer rod required for the application.

Product selection should be based on project requirements, design conditions, environmental exposure, and applicable project specifications. ASTM D1056 classification does not by itself indicate suitability for every application.

Sectors

Information

Contact us

Need Everlastic® Backer Rod for Your Project?

Williams Products provides quality cellular rubber materials and custom fabrication for concrete and construction applications. Contact us for pricing, availability, and custom fabrication options.

Send us a message

"*" indicates required fields